On the system of ensuring electrical safety of maintenance works performed on 35 – 750 kV power transmission lines being under induced voltage implemented in the Republic of Belarus

https://doi.org/10.24223/1999-5555-2018-11-2-154-160

Abstract

The article studies the matters of physics of interaction of parallel overhead power transmission lines. Cases are presented, where the maximum induced voltage values are expected on individual sections of closely approaching de-energized and energized power transmission lines. Possible scenarios are presented of direct contact with an unearthed conductor (wire) of OPL in the normal operation mode. Substantiation is presented of review of the list of the lines, which, when de-energized or earthed at terminal sections (in the switchgear of substations and power plants) have the values of induced voltage on the earthed conductors, as reduced to the maximum permissible continuous current of the affecting OPL, exceeding 25 V . Criteria are identified to classify OPL as being affected by induced voltage. The article considers organizational and technical procedures applied to provide safe maintenance works under induced voltage on de-energized overhead power lines (OPL) located within an area affected by energized OPL.  Attention is given to the detailed description of types of earthing of OPL, line equipment, working section and workplaces used by State Production Association Belenergo. The mathematical apparatus used in the analytical calculations of the induced voltage values has been analyzed. The technical implementation of acceptable schemes of performing the repair and maintenance works on the earthing of de-energized OPL is considered. Performing geophysical ground survey by the method of vertical electrical sounding at places of mounting special low-resistance earthing electrodes is proposed and implemented. The methodology is developed and tested for measuring induced voltage values, which sets the order of induced voltage measurements on de-energized OPL running close to energized OPL with the voltage 110 kV, and higher. Comparative analysis is presented of results of analytical calculations and experimental research. Conclusions are made supporting the approach adopted and confirming the expediency of the system of ensuring electrical safety of maintenance works performed on 35–750 kV power transmission lines being under induced voltage implemented in the Republic of Belarus.

About the Authors

M. A. Drako
Scientific Research and Design Republican Unitary Enterprise Belenergosetproekt (RUP BELENERGOSETPROEKT)
Belarus

1st Tverdy pereulok, 5, 220037, Minsk 



A. M. Korotkevich
Scientific Research and Design Republican Unitary Enterprise Belenergosetproekt (RUP BELENERGOSETPROEKT)
Belarus

1st Tverdy pereulok, 5, 220037, Minsk



V. N. Porshnev
State Production Association electricity "Belenergo"
Belarus

Ul. Karl Marx, 14, 220030, Minsk



References

1. Technical safety rules in the operation of electrical installations. Technical code of common practice 427-2012. Minsk: Minskenergo; 2013;: 1–148. (In Russ.)

2. Sharandin A. A. Induced voltage and voltage protection. Moscow: Energoprogress; 2016;: 1–40. (In Russ.)

3. Vantejev A. I. Problems of safe organization of works on overhead power lines. Moscow: Energoprogress; 2014;: 1–84. (In Russ.)

4. Tselebrovsky U. V. Safety of works on OPL under the induced voltage. Actual danger and voltage measurement methods. News of electrical engineering. 2009; 1(55): 54–27 (In Russ.).

5. Mikhailov M. I., Razumov L. D., Sokolov S. A. Electromagnetic influence on communication buildings. Moscow: Communication; 1979;: 1–264. (In Russ.)

6. Glushko V. I., Yamney O. E., Kovalev E. P., Naumenok N. A. Calculation of the induced volt-age on the electric lines and provision of safety work on these lines. Electricity. 1997; 8: 13–18. (In Russ.)

7. M. A. Drako, A. M. Korotkevich, E. P. Kovalyov The necessity of vertical electrical sounding of 35–750 kV support mounting location. Energy strategy. 2005; 1(43): 25–27. (In Russ.)

8. Electrical installations with voltage level up to 750 kV. Overhead electric lines and conductors, switching and transformer substations, electrical power and accumulator installations, electrical power installations of public facilities. Rules for design and electrical safety protection. Electricity metering. Acceptance test regulations: technical code of common practice 339-2011. Minsk: Minskenergo; 2011;: 1–601. (In Russ.)

9. Bokhan N. V., Glushko V. I., Kovalev E. P., Yamney O.E. Safe work on power lines under the induced voltage. Labour safety. 2007;: 3: 31–32. (In Russ.)

10. The methodology guidelines to defi ne the induced voltage on de-energized overhead electric lines, which are situated near the acting OPL: industry standard 56947007-29.240.55.018-2009. Мoscow: FSK EES; 2008;: 1–27. (In Russ.)


Review

For citations:


Drako M.A., Korotkevich A.M., Porshnev V.N. On the system of ensuring electrical safety of maintenance works performed on 35 – 750 kV power transmission lines being under induced voltage implemented in the Republic of Belarus. Safety and Reliability of Power Industry. 2018;11(2):154-160. (In Russ.) https://doi.org/10.24223/1999-5555-2018-11-2-154-160

Views: 661


ISSN 1999-5555 (Print)
ISSN 2542-2057 (Online)