The article presents the results of research on the eff ect of damage rate of steam turbine technological subsystems equipment on the operation of a power plant. It was revealed on the basis of analysis of reliability indicators of power units that malfunctions of steam turbine unit (STU) equipment accounted for 25 – 30 % of the total number of failures. The article presents the results of the malfunction analysis for the equipment of various STU technological subsystems operating in the power units and at cross-links power stations and leading to the turbine unit shutdown (failure). It is shown that critical equipment causing turbine unit shutdown in 70 or more percent of cases is represented by the equipment of three technological subsystems: condenser unit, oil supply subsystem and feed water subsystem. Based on the analysis results for operational documentation obtained at the Ural-Siberian region power plants for more than 300 power units with capacity of 200 to 800 MW, the article presents data on the eff ect of equipment failures at various technological subsystems on unplanned shutdowns of steam turbines. It also studies the basic malfunctions of the most critical equipment (that is of condenser, ejector, gland steam heaters, feedwater and condensate pumps, oil coolers, etc.) which can result both in its failure and in turbine unit functional shutdown. Statistical data is presented on the distribution of the causes of damage to condensers, ejectors, feedwater and condensate pumps and oil system equipment. Data presented in the article can be used to develop modules of technical condition monitoring and diagnostics as well as failure preventing measures for steam turbine technological subsystems equipment.

 

About the Authors

B. E. Murmansky
Ural Federal University named after the First President of Russia B. N. Yeltsin (URFU)
Russian Federation


K. E. Aronson
Ural Federal University named after the First President of Russia B. N. Yeltsin (URFU)
Russian Federation


Yu. M. Brodov
Ural Energy Institute (UralEnIn)
Russian Federation


References

1. The concept of a comprehensive system for monitoring the state of the equipment of a power unit / Aronson K. E., Akif'eva N. N., Brodov Yu. M., Bogatova T. F., Murmanskij B. E., Kortenko V. V. // 2002. Teploenergetika (2), с. 47 – 53.

2. Reliability indicators for general and auxiliary equipment of power units of Sverlovaenergo power stations / Yu. M. Brodov, B. E. Murmanskii, М. М. Mitelman, G. D. Buhman, V. A. Zaitsev // Electricheskiye stantsii. 1997. №5. P. 12 – 15.

3. Repair and technical maintenance of the steam turbine units equipment: directory: in 2 v. / Yu. M. Brodov, K. E. Aronson, Yu. M. Gofman, B. E. Murmanskii, M. A. Nirenshtein, A. Yu. Ryabchikov, P. N. Plotnikov; general edition by Yu. M. Brodov. Ekaterinburg: UrFU, 2011. 1029 p.

4. Analyses of the operation of power units for 150 – 200 MWt during 1986 – 2000 years period / SPO ORGRES, Moscow.

5. Analysis of indicators characterizing the reliability of cogeneration turbines / Murmanskii B. E., Brodov Y. M., Valamin A. E., Kogan P. V., Ioff e L. S. // 2011. Thermal Engineering 58(1), с. 41 – 45.

6. An analysis of indicators characterizing the reliability of auxiliary equipment of power units / Aronson K. E., Brodov Yu. M., Plotnikov P. N., Ryabchikov A. Yu., Murmanskii B. E., Nirenshtein M. A. // 2011.Thermal Engineering 58(8), с. 623 – 628.

7. Akolzin P. A. Corrosion and defense of the metal for heat-power engineering. М.: Energoizdat, 1982. 304 p.

8. Aronson K. E. Heat exchangers of power units: textbook for Universities / K. E. Aronson, S. N. Blinkov, V. I. Brezgin etc.; general edition by Yu. M. Brodov. Third edition: chfnged and added. Ekaterinburg: UrFU, 2014. 830 p.

9. Technical maintenance and repair of the steam turbine units heat exchangers : textbook for high schools / General edition by Yu. M. Brodov. Ekaterinburg: GOU VPO, UGTU-UPI, 2005. 304 p.

10. Brodov Yu. M. Analyses of reliability indicators for heat exchangers of power stations / Yu. M. Brodov, R. S. Reznikova, G. I. Krasnova, A. I. Chaika // Energomashinostroenie, 1982. №11. P. 35 – 39.

11. Damages review for heatmechanical equipment of power stations with transversal connections and for thermal networks during 1986 – 2000 years period / SPO ORGRES, Moscow.