Abstract

The article deals with application prospects of evaporation heat exchangers with capillary gap channels in the heat carrier boiling area within heliotechnical systems, for example, in desalination units. It shows that if capillary channels are used, heat exchange is 3–7 times higher than in case of conventional boiling conditions, and that steady boiling mode is still present even though heat flow density is 3–5 times less.