Estimating the permissible number of loading cycles for shutdown of high-pressure heaters of thermal power plants

Abstract

The article presents design analysis results for temperature fields in high pressure heater (HPH) elements of a TPP. It determines the permissible number of switching cycles of the HPH based on cyclic strength of the housing walls and the flanged joint membrane. A correlation is found between the position of the aggregate state limit and the cyclic strength of the heater elements; conditions are described under which the required cyclic strength is achieved

About the Authors

A. M. Antonova
Национальный исследовательский Томский политехнический университет
Russian Federation


A. V. Vorobiev
Национальный исследовательский Томский политехнический университет
Russian Federation


References

1. Иванов В.А. Регулирование энергоблоков. – Л.: Машиностроение, 1982. – 311 с.

2. ГОСТ Р 52857.6-2007 Сосуды и аппараты. Нормы и методы расчета на прочность. Расчет на прочность при малоцикловых нагрузках. Введен в действие 01.04.2008.


Review

For citations:


Antonova A.M., Vorobiev A.V. Estimating the permissible number of loading cycles for shutdown of high-pressure heaters of thermal power plants. Safety and Reliability of Power Industry. 2013;(2(21)):37-39. (In Russ.)