<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energsecurity</journal-id><journal-title-group><journal-title xml:lang="ru">Надежность и безопасность энергетики</journal-title><trans-title-group xml:lang="en"><trans-title>Safety and Reliability of Power Industry</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1999-5555</issn><issn pub-type="epub">2542-2057</issn><publisher><publisher-name>ООО «НПО Энергобезопасность»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24223/1999-5555-2022-15-4-278-283</article-id><article-id custom-type="elpub" pub-id-type="custom">energsecurity-848</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ПРОЕКТИРОВАНИЕ, ИССЛЕДОВАНИЯ, РАСЧЕТЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>DESIGN, RESEARCH, CALCULATIONS</subject></subj-group></article-categories><title-group><article-title>Анализ влияния уровней несинусоидальности напряжений в электросетях многоквартирных домов на надежность и эффективность работы трансформаторов</article-title><trans-title-group xml:lang="en"><trans-title>Analysis of the impact of non-sinusoidal voltage levels in the power grid of apartment buildings on the reliability and efficiency of transformers</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Султанов</surname><given-names>М. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Sultanov</surname><given-names>M. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>пр. Ленина, 69, 404111, г. Волжский</p></bio><bio xml:lang="en"><p>ave. Lenin, 69, 404111, Volzhsky</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Стрижиченко</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Strijichenko</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>пр. Ленина, 69, 404111, г. Волжский</p></bio><bio xml:lang="en"><p>ave. Lenin, 69, 404111, Volzhsky</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Янченко</surname><given-names>С. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Yanchenko</surname><given-names>S. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>пр. Ленина, 69, 404111, г. Волжский</p></bio><bio xml:lang="en"><p>ave. Lenin, 69, 404111, Volzhsky</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Филиал ФГБОУ ВО «НИУ «МЭИ» в г. Волжском</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Branch of FSBOU VO "National Research Institute "MPEI "in Volzhsky</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>09</day><month>02</month><year>2023</year></pub-date><volume>15</volume><issue>4</issue><fpage>278</fpage><lpage>283</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Султанов М.М., Стрижиченко А.В., Янченко С.А., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Султанов М.М., Стрижиченко А.В., Янченко С.А.</copyright-holder><copyright-holder xml:lang="en">Sultanov M.M., Strijichenko A.V., Yanchenko S.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.sigma08.ru/jour/article/view/848">https://www.sigma08.ru/jour/article/view/848</self-uri><abstract><p>Проанализированы эффекты массового внедрения энергосберегающего освещения на допустимый уровень загрузки питающего трансформатора, влияние несинусоидальности напряжения и тока на износ трансформатора. Искажения синусоидальной формы напряжений и токов приводят к возникновению дополнительных потерь мощности в трансформаторе. Они вызывают нагрев изоляции и обмоток трансформатора, увеличенные потери и ускоренный износ. Высшие гармонические составляющие напряжения и тока в сети напряжением 0,4 кВ вызваны наличием различных энергосберегающих ламп освещения с нелинейной вольт-амперной характеристикой, к которым относятся компактные люминесцентные и светодиодные источники света. В результате трансформатор, предназначенный для работы на частоте 50 Гц, испытывает дополнительное неблагоприятное воздействие в виде потерь мощности и ускоренного износа электрической изоляции, что приводит не только к ухудшению его технических и экономических эксплуатационных характеристик, но и к существенному снижению надежности, связанных с влиянием высших гармонических составляющих напряжения и тока на отказ оборудования. Показано, что отсутствие схем коррекции коэффициента мощности маломощных компактных люминесцентных и светодиодных ламп обуславливает рост несинусоидальности напряжения и тока по мере их распространения, что в свою очередь вызывает необходимость корректировки предельной нагрузки трансформаторов для обеспечения их номинального теплового режима. Одним из путей поддержания эксплуатационной надежности в таких условиях является ограничение нагрузки трансформатора в зависимости от уровня высших гармоник в сети, а также прогнозирование остаточного ресурса работающего трансформатора. Измерение значений текущих нагрузки трансформатора и уровней высших гармонических составляющих напряжения и тока позволит не только рассчитывать допустимый по условию износа изоляции коэффициент загрузки трансформатора, но и производить оценку текущего остаточного ресурса трансформаторного оборудования с применением нейросетевой модели.</p></abstract><trans-abstract xml:lang="en"><p>The effects of mass implementation of energy-saving lighting on the permissible level of loading of the supply transformer were analyzed. The influence of non-sinusoidal voltages and currents on transformer wear was analyzed. Distortions of sinusoidal shape of voltages and currents lead to additional power losses in transformer. They cause heating of the insulation and windings of the transformer, increased losses and accelerated wear and tear. Higher harmonic components of voltage and current in a 0.4 kV network are caused by the presence of various energy-saving lighting lamps with non-linear volt-ampere characteristic, which include compact fluorescent and LED light sources. As a result, the transformer designed to operate at a frequency of 50 Hz experiences an additional adverse effect in the form of power losses and accelerated wear of electrical insulation, which leads not only to the deterioration of its technical and economic performance characteristics, but also to a significant decrease in reliability associated with the influence of higher harmonic components of voltage and current on equipment failure. It is shown that the lack of power factor correction schemes for low-power compact fluorescent and LED lamps causes the growth of nonsinusoidal voltage and current as they spread, which in turn causes the need to adjust the limit load of transformers to ensure their rated thermal mode. One way to maintain operational reliability under such conditions is to limit the transformer load depending on the level of higher harmonics in the network, as well as to predict the residual life of the operating transformer. Measuring the values of current transformer load and current levels of higher harmonic components of voltage and current will allow not only to calculate an acceptable load factor of the transformer (for the condition of insulation wear), but also to estimate the current residual life of transformer equipment using a neural network model.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>качество электроэнергии</kwd><kwd>несинусоидальность напряжений</kwd><kwd>нагрузка трансформатора</kwd><kwd>надежность</kwd></kwd-group><kwd-group xml:lang="en"><kwd>power quality</kwd><kwd>non-sinusoidal voltages</kwd><kwd>transformer load</kwd><kwd>reliability</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Исследование выполнено при финансовой поддержке государственного контракта Российской Федерации № FSWF-2020-0025 "Разработка методики и анализ методов обеспечения безопасности и конкурентоспособности объектов электроэнергетики на основе цифровых технологий".</funding-statement><funding-statement xml:lang="en">The work was carried out with the ﬁnancial support of the state task of the Russian Federation FSWF 2020-0025 "Development of methods and analysis of ways to achieve a high level of safety and competitiveness of facilities of energy systems based on digital technologies."</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 14209-85 (МЭК 354-91) Межгосударственный стандарт. Руководство по нагрузке силовых масляных трансформаторов.</mixed-citation><mixed-citation xml:lang="en">GOST 14209-85 (IEC 354-91) Interstate Standard. Guidelines for loading of power oil transformers.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Бондаренко Н. Е., Латышов К. В., Стрижиченко А. В. Влияние высших гармонических составляющих напряжения на потери мощности в трансформаторе. // Энерго- и ресурсосбережение: промышленность и транспорт 2019; (2): 10 – 13.</mixed-citation><mixed-citation xml:lang="en">Bondarenko N. E., Latyshov K. V., Strizhichenko A. V. Inﬂuence of higher harmonic components of voltage on power losses in transformer. // Energy and resource saving: industry and transport 2019; (2): 10 – 13.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Оценка влияния высших гармонических составляющих тока на скорость относительного износа витковой изоляции силового трансформатора / Н. Е. Бондаренко, К. В. Латышов, Е. Г. Зенина, А. В. Стрижиченко. Международная научно-практическая конференция, г. Волжский, 23 – 26 октября 2019 г.: тезисы докладов. – Волжский: Филиал ФГБОУ ВО «НИУ «МЭИ» в г. Волжском 2020;: 40 – 42.</mixed-citation><mixed-citation xml:lang="en">Assessment of the inﬂuence of higher harmonic components of current on the rate of relative wear of winding insulation of power transformer / N. E. Bondarenko, K. V. Latyshov, E. G. Zenina, A. V. Strizhichenko. International scientiﬁc and practical conference, Volzhsky, October 23 – 26, 2019: abstracts. – Volzhskiy: Branch of Federal State Budgetary Educational Institution of Higher Professional Education "National Research University "MPEI" in Volzhskiy 2020;: 40 – 42.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Оценка надежности работы электрооборудования при наличии высших гармоник токов и напряжений / М. М. Султанов, Е. Г. Зенина, В. Г. Кульков, О. И. Желяскова / Электротехника 2021, (8): 62 – 68.</mixed-citation><mixed-citation xml:lang="en">Assessment of reliability of electrical equipment in the presence of higher harmonics currents and voltages / M. M. Sultanov, E. G. Zenina, V. G. Kulkov, O. I. Zhelaskova / Electrotekhnika 2021(8): 62 – 68.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 32144-2013 Электрическая энергия. Совместимость технических средств электромагнитная. Нормы качества электрической энергии в системах электроснабжения общего назначения.</mixed-citation><mixed-citation xml:lang="en">GOST 32144-2013 Electrical Energy. Compatibility of technical means electromagnetic. Quality standards of electric energy in general purpose power supply systems.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Влияние показателей качества электроэнергии на надежность работы силового трансформаторного оборудования электростанций и распределительных сетей / The third conference «Problems of thermalphysics and power engineering» / А. В. Стрижиченко, Е. Г. Зенина, М. М. Султанов, О. И. Желяскова / Journal of physics: conference series 2020, 1683: 1 – 5.</mixed-citation><mixed-citation xml:lang="en">Inﬂuence of power quality parameters on reliability of power transformer equipment of power plants and distribution networks / The third conference "Problems of thermal physics and power engineering" / A. V. Strizhichenko, E. G. Zenina, M. M. Sultanov, O. I. Zhelyaskova / Journal of physics: conference series 2020; 1683: 1 – 5.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">C57.110:2008 "IEEE recommended practice for establishing liquid-ﬁlled and dry-type power and distribution transformer capability when supplying non sinusoidal load currents – red line" 2008.</mixed-citation><mixed-citation xml:lang="en">C57.110:2008 "IEEE recommended practice for establishing liquid-ﬁlled and dry-type power and distribution transformer capability when supplying non sinusoidal load currents – red line", 2008.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Investigation on dielectric breakdown behavior of thermally aged cross-linked polyethylene cable insulation / Ch. Kim, P. Jiang, F.Liu, S. Hyon, M. Ri, Y. Yu, M. Ho // Polymer Testing 2019;: 80.</mixed-citation><mixed-citation xml:lang="en">Investigation on dielectric breakdown behavior of thermally aged cross-linked polyethylene cable insulation / Ch. Kim, P. Jiang, F. Liu, S. Hyon, M. Ri, Y. Yu, M. Ho // Polymer Testing 2019;: 80.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Development of a centralized system for data storage and processing on operation modes and reliability indicators of power equipment / M. M. Sultanov, Y. A. Gorban, A. A. Smirnov, V. A. Yurov / Proceedings of the 3rd 2021 International Youth Conference on Radio Electronics, Electrical and Power Engineering, REEPE 2021, 2021, 9388022</mixed-citation><mixed-citation xml:lang="en">Development of a centralized system for data storage and processing on operation modes and reliability indicators of power equipment / M. M. Sultanov, Y. A. Gorban, A. A. Smirnov, V. A. Yurov / Proceedings of the 3rd 2021 International Youth Conference on Radio Electronics, Electrical and Power Engineering, REEPE 2021, 2021, 9388022.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Разработка комплексной системы оценки технического состояния генерирующего оборудования с использованием нейросетевого моделирования // П. В. Шамигулов, М. М. Султанов, Ш. М. Милитонян, Ю. А. Горбань / Вестник МЭИ 2022; 6: 136 – 145. DOI: 10.24160/1993-6982-2022-6-136-145.</mixed-citation><mixed-citation xml:lang="en">Development of complex system of estimation of technical state of generating equipment with use of neural network simulation // P. V. Shamigulov, M. M. Sultanov, Sh. M. Militonyan,Yu. Gorban 2022. №6: 136 – 145. DOI: 10.24160/1993-6982-2022-6-136-145.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
