<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energsecurity</journal-id><journal-title-group><journal-title xml:lang="ru">Надежность и безопасность энергетики</journal-title><trans-title-group xml:lang="en"><trans-title>Safety and Reliability of Power Industry</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1999-5555</issn><issn pub-type="epub">2542-2057</issn><publisher><publisher-name>ООО «НПО Энергобезопасность»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24223/1999-5555-2019-12-3-213-219</article-id><article-id custom-type="elpub" pub-id-type="custom">energsecurity-658</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОПЫТ ЭКСПЛУАТАЦИИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>OPERATING EXPERIENCE</subject></subj-group></article-categories><title-group><article-title>Об эффективности использования двухступенчатого подогрева сетевой воды на теплоэлектроцентралях с турбинами Т-250/300-240</article-title><trans-title-group xml:lang="en"><trans-title>Efficiency of two-stage heating of water on CHP plant with turbines of type T-250/300-240</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Ильин</surname><given-names>Е. Т.</given-names></name><name name-style="western" xml:lang="en"><surname>Ilin</surname><given-names>E. T.</given-names></name></name-alternatives><bio xml:lang="ru"><p>кафедра ТЭС</p></bio><bio xml:lang="en"><p>Department TPP</p></bio><email xlink:type="simple">ilyinet@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Печенкин</surname><given-names>С. П.</given-names></name><name name-style="western" xml:lang="en"><surname>Pechenkin</surname><given-names>S. P.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Светушков</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Svetushkov</surname><given-names>A. V.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Козлова</surname><given-names>Ю. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Kozlova</surname><given-names>J. A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Федеральное государственное бюджетное образовательное учреждение высшего образования "Национальный исследовательский университет "МЭИ" (ФГБОУ ВО «НИУ «МЭИ»)</institution><country>Россия</country></aff><aff xml:lang="en"><institution>National Research University "Moscow Power Engineering Institute"</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>21</day><month>11</month><year>2019</year></pub-date><volume>12</volume><issue>3</issue><fpage>213</fpage><lpage>219</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Ильин Е.Т., Печенкин С.П., Светушков А.В., Козлова Ю.А., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Ильин Е.Т., Печенкин С.П., Светушков А.В., Козлова Ю.А.</copyright-holder><copyright-holder xml:lang="en">Ilin E.T., Pechenkin S.P., Svetushkov A.V., Kozlova J.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.sigma08.ru/jour/article/view/658">https://www.sigma08.ru/jour/article/view/658</self-uri><abstract><p>В летний и неотопительный период большинство теплофикационных турбин работают только с одним включенным нижним теплофикационным отбором, так как при работе турбины существует ряд ограничений по максимальному и минимальному давлению в верхнем и нижнем отборе. Для турбины Т-250/300-240 величина минимально-допустимого давления в верхнем отборе согласно условиям завода изготовителя составляет 0,06 МПа. В неотопительный летний период, а также в начале и конце отопительного периода температура прямой сетевой воды понижается до 70–75°С. В этом случае для поддержания температуры сетевой воды на заданном уровне давление в верхнем отборе уменьшается ниже минимально-допустимого уровня. В результате турбоустановки работают с одним включенным нижним подогревателем сетевой воды (ПСГ-1), позволяющим реализовать такой режим, но это приводит к ухудшению показателей тепловой экономичности. Предложен ряд мероприятий, позволяющих исключить данные ограничения и осуществлять подогрев сетевой воды с использованием двух ступеней подогрева. В этом случае при подключении второго отбора давление в нём поддерживается на минимально допустимом уровне. Соблюдение графика теплосети обеспечивается за счёт обвода части сетевой воды помимо группы сетевых подогревателей. При работе в таком режиме увеличивается срабатываемый теплоперепад в турбине, уменьшается расход охлаждающего пара в часть низкого давления и соответственно в конденсатор и снижаются температурные напоры в сетевых подогревателях. Приведены результаты исследования режимов работы турбины Т-250/300-240 в неотопительный и переходный период с одним и двумя теплофикационными отборами. Проведена оценка экономической эффективности использования данных режимов в зависимости от условий эксплуатации, которая показала эффективность применения режима в летний и неотопительный период. Определены границы эффективности использования данных режимов.</p></abstract><trans-abstract xml:lang="en"><p>During non-heating and transition period, most of cogeneration turbines operate with a lower heat extraction section actuated only due to a number of restrictions on the maximum and minimum pressure levels in the upper and lower heat extraction sections at operation of the turbine. For turbines of model T-250/300-240, the minimum permissible level of steam pressure in the upper heat extraction section, according to manufacturer data, is set to 0.06 MPa. During the non-heating and transition period, the supply water temperature is usually set in the range of 70–75°С. In order to maintain that temperature of supply water, the steam pressure in the upper heat extraction section should be below the minimum permissible level. As a result, the turbine operates with only the low-pressure heat extraction section actuated, which ensures operation without restrictions, but with a lower efficiency. The authors have introduced a set of measures, which enable to avoid those restrictions and implement two-stage heating of supply water. In this case, on connection of the upper heating extraction section, the pressure in the same is maintained at the minimum permissible level. Heat output characteristics are provided by having some of supply water delivered bypassing the group of network heaters. This operational mode enables to increase the turbine actual heat drop, to reduce the cooling steam flow into the low-pressure section and, accordingly, into the condenser, and to reduce temperature drops in network water heaters. Results of the research of operational modes for turbines of type T-250/300-240 in the non-heating and transition period with one and two-stage heating are provided. The economic efficiency of proposed operational modes was researched, which shows the effectiveness of those modes during non-heating and transition period. The limits of the efficiency of using these modes are determined.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>теплофикация</kwd><kwd>турбина Т-250/300-240</kwd><kwd>сетевые подогреватели</kwd><kwd>двухступенчатый подогрев</kwd><kwd>частичный обвод</kwd><kwd>переходный и неотопительный период</kwd><kwd>повышение эффективности</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Central heating</kwd><kwd>turbine T-250/300-240</kwd><kwd>network heater</kwd><kwd>two-stage heating</kwd><kwd>partial bypassing</kwd><kwd>nonheating and transition period</kwd><kwd>efficiency improvement</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Инструкция по эксплуатации турбоустановки с турбиной Т-250/300-240. ТМТ-110650-2. Екатеринбург 2017;: 187.</mixed-citation><mixed-citation xml:lang="en">Instruction manual for turbine type T-250/300-240. TMT-110650-2. Ekaterinburg 2017;: 187. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Соколов Е. Я. Теплофикация и тепловые сети. 7-е издание. М.: Издательство МЭИ 2001;: 472.</mixed-citation><mixed-citation xml:lang="en">Sokolov E. J. Central heating and heating networks. 7th edition. M.: Publishing house of MPEI. 2001;: 472. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Ильин Е. Т., Печенкин С. П., Крыленко М. А. Повышение тепловой экономичности теплофикационных турбин в переходный и неотопительный периоды при использовании двухступенчатого подогрева сетевой воды с применением частичного обвода сетевых подогревателей. Энергосбережение и Водоподготовка. 2014; (3): 27–30.</mixed-citation><mixed-citation xml:lang="en">Ilin Е. Т., Pechenkin S. P., Krylenko M. A. Stage heating network of water with the use of partial bypass line heaters//Energy saving and Water treatment. 2014; (3); 27–30. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Заводские характеристики «График расчётных температурных напоров сетевого подогревателя ПСГ-5000-2.5(3)-8». Инструкция по эксплуатации теплофикационной установки турбины Т-250/300- 240-3 2017.</mixed-citation><mixed-citation xml:lang="en">Factory specifications «Underheating temperature graph of network heater model HNH-5000-2.5(3)-8» Instruction manual of network heating system for turbine type T-250/300-240 2017. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Строительные нормы и правила: СНиП 23.01.99 – 85. СТРОИТЕЛЬНАЯ КЛИМАТОЛОГИЯ [Текст]: нормативно-технический материал. Москва. 2012; 109.</mixed-citation><mixed-citation xml:lang="en">Building codes and regulations: BC&amp;R 23.01.99 – 85. Construction climatology [Text]: regulative technical material. Moscow. 2012: 109. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Диспетчерский график теплосети для ТЭЦ с турбинами Т-250/300-240 ПАО «Мосэнерго» 2017.</mixed-citation><mixed-citation xml:lang="en">Operation schedule of the heating system for CHP plant with turbine model Т-250/300-240 PSC «Mosenergo» 2017. (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">АО «Администратор торговой системы оптового рынка электроэнергии» [Электронный ресурс]: оптовый рынок электроэнергии и мощности URL: https://www.atsenergo.ru/ (дата обращения: 01.05.2017).</mixed-citation><mixed-citation xml:lang="en">JSC «Administrator of trading system of energy market» [Online resourse]: Wholesale market of electric energy and power URL: https:// www.atsenergo.ru/ (reference date: 01.05.2017). (In Russ.)</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">ООО «Газпром межрегионгаз Москва» [Электронный ресурс]: Тарифы на газ для промышленных потребителей URL: http://gazmsk. ru/pages/110_0.htm (дата обращения: 01.05.2017).</mixed-citation><mixed-citation xml:lang="en">LLC «Gazprom mezhregiongaz Moscow» [Online resourse]: Natural gas tariffs for industrial companies URL: http://gazmsk.ru/pages/110_0. htm (reference date: 01.05.2017). (In Russ.)</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
