<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">energsecurity</journal-id><journal-title-group><journal-title xml:lang="ru">Надежность и безопасность энергетики</journal-title><trans-title-group xml:lang="en"><trans-title>Safety and Reliability of Power Industry</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1999-5555</issn><issn pub-type="epub">2542-2057</issn><publisher><publisher-name>ООО «НПО Энергобезопасность»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.24223/1999-5555-2018-11-1-21-29</article-id><article-id custom-type="elpub" pub-id-type="custom">energsecurity-544</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЩИЕ ВОПРОСЫ НАДЕЖНОСТИ И БЕЗОПАСНОСТИ ЭНЕРГЕТИКИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>GENERAL ISSUES RELATED TO RELIABILITY AND SAFETY OF THE POWER INDUSTRY</subject></subj-group></article-categories><title-group><article-title>Исследование надежности ОЭС Юга в связи с присоединением новых сосредоточенных нагрузок (часть 1)</article-title><trans-title-group xml:lang="en"><trans-title>Investigation of the reliability of the IPS of South in connection with the acquisition of new concentrated loads (part 1)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Непомнящий</surname><given-names>В. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Nepomnyashchiy</surname><given-names>V. A.</given-names></name></name-alternatives><email xlink:type="simple">nva.sbor@mail.ru</email></contrib></contrib-group><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>13</day><month>04</month><year>2018</year></pub-date><volume>11</volume><issue>1</issue><fpage>21</fpage><lpage>29</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Непомнящий В.А., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Непомнящий В.А.</copyright-holder><copyright-holder xml:lang="en">Nepomnyashchiy V.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.sigma08.ru/jour/article/view/544">https://www.sigma08.ru/jour/article/view/544</self-uri><abstract><p>Рассматриваются вопросы надежности функционирования магистральных сетей 500 – 220 кВ ОЭС Юга и влияние присоединения новых нагрузок на их работу. В 1-й части статьи показано, что уже в настоящее время действующие магистральные сети имеют уровень надежности (вероятность бесперебойной работы) 0,980, что соответствует продолжительности аварийных состояний сетей 175 ч/год. С подключением новых потребителей загрузка магистральных сетей 500 – 330 кВ существенно возрастает, что резко снижает резерв их пропускной способности и понижает надежность их функционирования, особенно в периоды про- ведения планово-профилактических ремонтных работ в сетях 500 кВ. Передача электроэнергии и мощности из ОЭС Юга в дополнительную новую энергосистему по действующим магистральным сетям в пределах 800 – 850 МВт особенно в летний период (в период проведения ремонтных кампаний) существенно снижает надежность их работы до вероятности бесперебойного функционирования 0,965. Это увеличивает вероятную длительность аварийных состояний сети до 300 – 310 ч/год и может стать источником системных аварий, особенно в режимах с плановыми ремонтами основных ЛЭП 500 кВ, приводящими к понижению пропускной способности сети. Близкая к предельным значениям загрузка магистральных сетей 500 – 330 – 220 кВ в доаварийных нормальных режимах создает дополнительные негативные условия их функционирования, так как в этих случаях аварийные отключения даже малоответственных в режимном отношении линий электропередачи может стимулировать развитие системных аварий.</p></abstract><trans-abstract xml:lang="en"><p>The paper considers the matters of operational reliability of 500 – 220 kV trunk networks of the IPS of South and the impact of connection of new loads. As is shown in part 1 of the paper, at present the operating trunk networks have had the reliability level (the probability of failsafe operation) at 0.980, which corresponds to the duration of emergency conditions of networks at 175 hrs per annum. With the connection of new consumers the load on 500 – 330 kV trunk networks has increased significantly, which has sharply reduced their throughput capacity margin and lowered their operational reliability, particularly at periods of scheduled maintenance work on 500 kV networks. The transfer electric energy and power from the IJS of the South in additional new energy system on existing backbone networks in the range of 800 – 850 MW, especially in the summer (during the maintenance campaigns) significantly reduces their operational reliability considerably to the failsafe operation probability of 0.965. This extends the probable duration of emergency conditions of network up to 30 – 310 hrs a year and may become a source of systemic emergencies, especially in operating modes with scheduled repair of the main 500 kV power transmission lines that would predetermine a decline in the throughput capacity of the network. Loading the 500 – 330 – 220 kV trunk networks to levels close to the limit values in pre-emergency normal operating modes creates additional adverse conditions for their operation, as in these cases emergency shutdowns of even low criticality power transmission lines could stimulate development of systemic emergencies.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>надежность</kwd><kwd>системные аварии</kwd><kwd>ущерб</kwd><kwd>схема электроснабжения</kwd></kwd-group><kwd-group xml:lang="en"><kwd>reliability</kwd><kwd>system emergencies</kwd><kwd>damage</kwd><kwd>power supply arrangement</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А. Надежность подстанций 1150 – 35 кВ с различным схемами распределительных устройств высокого напряжения. // Энергоэксперт. 2014. №6. С. 23 – 39.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Reliability of substations 1150 – 35 kV with various schemes of switchgears of higher voltage. // Energoexpert. 2014. №6. p. 23 – 39.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А. Надежность работы элементов электрических сетей 1150 – 35 кВ. // Энергоэксперт. 2012. №4. С. 26 – 40.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Reliability of the operation of electrical network elements 1150 – 35 kV. // Energoexpert. 2012. №4. p. 26 – 40.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А. Экономико-математическая модель надежности энергосистем и их электрических сетей. // Электричество. 2011. №2. С. 5 – 16.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Economic-mathematical model of reliability of power systems and their electrical networks. // Electricity. 2011. №2. p. 5 – 16.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А. Моделирование надежности электрических сетей. // Надежность и безопасность энергетики. 2014. №3. С. 2 – 15.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Modeling of reliability of electric networks. / Reliability and safety of power engineering. 2014. №3. p. 2 – 15.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А., Овсейчук В. А., Жежеленко И. В. Электро-снабжение потребителей. Нормирование надежности и качества. // Новости электротехники. 2014. №5. С. 17 – 25.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Valery A. Ovseychuk, Igor V. Zhezhelenko. Electricity supply to consumers. Rationing of reliability and quality. // Electrical Engineering News. 2014. №5. p.17 – 25.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Непомнящий В. А. Агрегированные значения удельных ущербов от нарушений электроснабжения. // Академия энергетики. 2015. №2. С. 58 – 68.</mixed-citation><mixed-citation xml:lang="en">Nepomnyashchiy V. A. Aggregated values of speciﬁ c damagess from interruption of power supply. // Academy of Power Engineering. 2015. №2. p. 58 – 68.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
